2012, 9900 Elite ESP, OEC, C-Arm


ID Number: 58778
Updated: 03-06-24 
Date Posted: 03-04-24 
Quantity: 1 
Manufacturer: OEC 
Description: C-Arm 
Type: Full Size 
Model: 9900 Elite ESP 
DOM: 2012 
Condition: Good 
Older listings 'may' have already been sold.  
..
Location: Midwest, US 
Installed: ?  
Warranty:  
Availability: 03-06-24 
Inspect Date:  

Seller Type:

Dealer:

Dealer 

Sell Price:

Details: 2017 OEC 9900 ELITE GSP C-ARM
12" II
• 60kHz high frequency
• 15kW power
• Up to 120kVp
• Up to 75mA for radiographic film exposure
• Continuous high level fluoro (HLF) up to 20mA
• Digital spot up to 75mA X-ray Tube
• Rotating anode X-ray tube
• 0.3mm and 0.6mm focal spots
• Anode heat capacity: 300,000 HU (per IEC 60613)
• Anode cooling rate: 85,000 HU/min.
• Housing heat capacity: 1,600,000 HU
• Standard housing cooling 15,000 HU/min.
• Passive housing cooling system: 22,500 HU/min. (Standard on 12 inch (31 cm) I.I. systems.
• Digitally adjusts image display
• Automatic image update -Image rotation -Image reversal (side-to-side) -Image invert (top-to-bottom)
• Image positioning without additional exposure PreView™ Collimator
• On-screen collimator position indication
• PreView™ iris collimator
• PreView™ Tungsten rotatable double leaf collimator
• Adjusts collimators without X-ray exposure Fluoro Mode
• kVp range: 40 -120 • mA range: 0.2 - 10 normal mode 1.0 - 20 HLF (high level fluoro)
• Auto and manual fluoro modes
• AutoTrak™ ABS varies mA, kVp, camera gain Pulsed Fluoro Mode
• kVp range: 40 - 120
• mA range: 0.2 - 10
• Pulse rate: 1, 2, 4, 8
• Pulse width: 25 or 50ms
• AutoTrak™ ABS, mA, kVp, camera gain
• Reduces X-ray dose to patient and operator High Level Pulsed Fluoro
• kVp range: 40 - 120
• mA range: 1 - 40
• Pulse rate: 1, 2, 4, 8
• Pulse width: 25 or 50ms
• AutoTrak™ ABS, mA, kVp, and camera gain
12” Image Intensifier
• Tri-mode 12”/9”/6” (31cm/23cm/15cm) image intensifier
• Minimum central resolution (at monitor): - 12” (31cm): 1.6 lp/mm - 9” (23cm): 2.2 lp/mm - 6” (15cm): 2.6 lp/mm
• DQE: 65% (typical)
GSP Platform
• 1k x 1k x 16 bit image processing
• Preset Imaging Profiles - 9800 - General - Orthopedic - Spine
• Noise filter with on-screen indicator
• Minimal difference spatio-temporal noise filter (MDST)
• Real time dynamic range management (DRM)
• Automatic digital brightness and contrast control
• Manual digital brightness and contrast control
• Negate mode
• Save and auto-save feature
• Swap and auto-swap feature
• Patient information - Examination list - Customized patient information
• Customize functions - Workstation set-up - Mainframe set-up - Patient information set-up - Date/time set-up - DICOM interface set-up
• Last image hold
• 63 image storage
• CD/DVD burner with DICOM viewer for displaying images on PC platforms - 512 x 512 or 1k x 1k
• Integrated DICOM interface (store, print, worklist, and query/retrieve)
• HIPAA SecureViewฎ - Password protection - Blank screen function - Delete all
AVAILABLE NOW IN THE MIDWEST
 

Canโ€™t Find What You Need?

Post an "Equipment Wanted" listing:

Post Equipment Wanted »

Have Something to Sell?

Reach thousands of buyers by posting your equipment for sale:

Post Equipment For Sale »