ID Number: |
60017 |
Updated: |
03-19-25 |
Date Posted: |
03-19-25 |
Quantity: |
1 |
Manufacturer: |
Quantum |
Description: |
Rad Room |
Type: |
DR - Floor Mount Tube |
Model: |
DS |
DOM: |
0 |
Condition: |
Good |
Older listings 'may' have already been sold.
| |
|
.. |
|
|
Location: |
Midwest, US |
Installed: |
? |
Warranty: |
|
Availability: |
03-20-25 |
Inspect Date: |
|
Seller Type:
Dealer:
|
Dealer |
Sell Price:
|
|
Details: |
QUANTUM DS FLOOR MOUNTED RAD ROOM
CANON 55G PACKAGE
RC-OPC-W 22” Wide-Screen Touch-Panel LCD Monitor Operator Console
· Operator’s graphical user interface for Modality Worklist query, patient registration & exam configuration, image acquisition, image preview & QC, integrated generator, DICOM Print & Store
· Wide-screen all-in-one display presents the Canon DR operator interface combined with the full-
featured generator console interface and with thumbnail images displayed for all previously acquired
images for the current patient
· Touch-panel screen appropriately displays alpha or numeric software-keyboard whenever operator
entry is required, essentially fully functional without a mouse or keyboard (although mouse and
keyboard are included)
Q-CONNECT Generator Integration to DR Console for CXDI Series
· Quantum Q-Connect Integrated Software & License for CXDI Series
· Generator mini-control with on/off switch and prepare/expose hand switch
· All generator service configuration, calibration, and diagnostics operated from DR console
· High-speed Ethernet interface CAT5 cables
· Includes QG-DIG-INT: digital electronics Interface with synchronization to Quantum x-ray generator
R-MLT Canon LANMIX MLT(M) & MLT(S) Image Processing Software
· Multi-frequency Laplacian image processing for consistent grey scale presentation of both bone and
soft tissue
· Enhances both high-contrast and low-contrast visualization
· Preset and user-adjustable multi-frequency dynamic range, noise reduction, and edge enhancement
RC-CPU-4 Canon CXDI FC-E21A Computer Control Station with CXDI
· 80GB HD with temporary storage capacity of over 4,000 raw data images
· DICOM 3.0 compliant print and storage SCU as CR or DX Modality
· IHE Profiles include; Basic Security – User authentication, Audit Log, Time Synchronization, Node
Authentication
· User-customized anatomical programming for receptor, orientation, Procedure Step definition, image
processing presets, Software Grid Suppression, MTF anatomical filters and intensity, Dynamic Range,
Edge enhancement, noise reduction
· Dual RJ45 Ethernet: 100M-bit interface to detectors, 1G-bit interface to RIS/PACS
· Logitech 2-button Mouse, Balkin Classic PS/2 Keyboard
· Operates in Standard Mode (no Login) or Secure Mode (User Authentication with auto-timeout)
· Image QA features including; Contrast, Brightness, Crop, Annotate, Magnification, Edge enhancement
· Maintenance QA includes SMPTE pattern and detector calibration with annual on-screen reminder
DICOM Store SCU for electronic archive to PACS with up to 2 destinations selectable (total 4 configurable),
network transmission configurable as automatic or manual, with Queue Manager
· DICOM Print SCU for hard copy film with up to 2 destinations selectable (total 4 configurable),
network transmission configurable as automatic or manual, with Queue Manager. Print Formatting
allows pre-exposure and post-exposure Multi-Formatting and selectable print methods for fixed ratio,
life size, and fit-to-film.
· Post-Study Image Recall, QA edit, & DICOM Print & Store Resend
· Reject/Retake/Un-Reject: Reject Reason annotations, monthly Reject Reporting (as .csv file exported
to admin)
QG-40 40 kW/125 kVp “ODYSSEY HF” Digital Deluxe Radiographic Generator
· Digital Imaging Ready, ULTRA High Frequency Power, 120 kHz PLUS
· 40 kW maximum output; (according to IEC 60601)
· mA Range: 25 to 500
· kVp Range: 40 to 125 kVp, in 1 kVp increments
· mAs Range: 0.025 – 600
· Timer Range: 0.001 - 6.3 seconds
· “APR” Anatomical Programmed Radiography (100 APR Views / 5000 Techniques) for Std. and Custom
Views
· Graphic LCD Display for APR and Technique Information, includes Date/Time Feature
· Self-Diagnostics, Anode Heat Monitor, Error Messaging, Auto Shut-off Timer, History Reporting Log, RS-
232 Port
*Nominal Input power: 208 - 240 VAC (+/- 10%) Single Phase; (Three Phase Input: Optional)
QG-AEC Automatic Exposure Control: (AEC) electronics for “ULTRA HF” generators
R10-T140 X-Ray Tube: 3” Radiographic X-Ray Tube
· 0.6/1.2 mm focal spot sizes with 300,000 Heat Unit capacity
· 150 kVp, High/standard speed rotor, 12° anode target angle, 90° arms
R70-40 High Voltage Cables: One Pair, 40 ft. long (12 meters) with Federal Terminals
QS-550 Deluxe Floor Mounted Tubestand
· Floor Mounted tubestand with 10 ft. long tracks and 98” (249 cm) of longitudinal travel
· Deluxe Handgrips: multi-function, fingertip controls for horizontal, vertical, transverse, and longitudinal movements
· Includes “All Locks” release switch and auto-stop sensor for horizontal/vertical adjustments
· Vertical Travel of 60.5” (154 cm) with minimum floor to focus distance of 13.75” (35 cm)
· FAIL-SAFE electromagnetic braking system and integral counterbalancing ensure safe, easy use
· Column Rotation (±180°), Transverse Arm (10-inch travel)
· Tube Angulations of ±135° with detents at 0°, ±90°
· Cable concealment and management system
QS-55T Trunnion Rings: For tube head rotation of -20°/+45° with dual angle guides
QT-750-D “QUIET-LIFT” Elevating / Float-Top Radiographic Table: for Direct Digital (DR)
· 650 lbs. (295.5 kg.) Patient Weight Capacity
· Elevating Range of 21” - 32.5” (53 - 83 cm) with collision avoidance electronics and safety lock-out control switch
· Tabletop length: 85” (216 cm) with 32” (82 cm) of longitudinal travel
· Tabletop width: 35.5’ (90 cm) with 11.5” (29.2 cm) of transverse travel; (Extra wide design, for large patient
comfort)
· Flat top design for easy patient transfer and cleaning, with low absorption material
· FAIL-SAFE electromagnetic braking system ensure safe, easy use
· Recessed Foot Switches for all table movements, with float-top hand control switch
· Adjustable patient handgrips along concealed accessory rails
· Power input: 115 VAC / 60 Hz / single phase / 10 Amp (Specify for International use: 220 VAC / single
phase / 50Hz)
· Includes QT-DIG-INT: QT-750 Interface for Direct Digital (DR) Receptor Mounting
R-CXDI-55G Canon “Thin-Lightweight” CXDI-55G: 14”x17” Portable Digital Radiography
Detector (G 2 O 2 S)
· Gadolinium-Oxysulfide scintillator, LANMIT 4, amorphous-Silicon TFT
· Imaging Area: 14” x 17” (35cm x 43cm)
· Pixel Array: 2208 x 2688 pixels (5.9 million pixels)
· Pixel Size: 160 micron (High Resolution 3.1 Lp/mm)
· Grayscale: 12 bit, 4096 gradations (14-bit A/D)
· Preview Image display <5 seconds
· Dimensions: 18.9” X 18.9” X 0.6” (480mm x 481mm x 15mm)
· Weight: 7.5 lbs. (3.4kg)
· 25.5’ (7.8 meter) “detachable” detector cable
· Remote power On/Off switch with 65.6’ (20 meter) interface cable
· * Includes “Power Box II” (1877A217) and Ethernet interface for 55G
R80-AEC Ionization Chamber for Digital: with three (3) Fields for use with QT-750 Table
R20-1010M 10:1 ratio, 103L, 100cm focus anti-scatter Grid: for CXDI-55G use with QT-750
Table
Q-DRTray-R Digital Tray with “Rotating Feature” and Cabinet; Landscape/Portrait rotation of
portable detector; Substitute for Q-DRTray
· Allows for quick and controlled manual rotation of the digital receptor within tray
· One handed manual rotation Portrait/Landscape in swivel based tray design
QW-420-D “VERTI-Q” Vertical Wall Stand for Direct Digital (DR); indicate left or right hand
load
· Vertical travel: 60.0” (153 cm)
· Minimum center pixel-to-Floor Distance: 13.75” (35 cm)
· Features the exclusive “EZ-GLIDE” Hand control for easy and precise movement, Grip rotates +105º
· FAIL-SAFE electromagnetic vertical braking system and integral counterbalancing ensure safe, easy
use
· Heavy Duty Single-column structure; floor-to-wall or floor-to-ceiling mount
· Includes QW-DIG-INT: QW-420 Interface for Direct Digital (DR) Receptor Mounting
QW-HG30 Patient “Overhead” Handgrip: Mounts to “VERTI-Q” Wall Stand
R80-AEC Ionization Chamber with three (3) Fields; for use with QW-420 Wall
Stand
R20-1010L 10:1 ratio, 103L, 150cm focus anti-scatter Grid: for CXDI-55G use with QW-420
Wall Stand
Q-DRTray-R Digital Tray with “Rotating Feature” and Cabinet; Landscape/Portrait rotation of
portable detector; Substitute for Q-DRTray
· Allows for quick and controlled manual rotation of the digital receptor within tray
· One handed manual rotation Portrait/Landscape in swivel based tray design
R40-M-P “Progeny MC150” Manual Collimator:
· Laser light for patient and cassette tray positioning, plus rectangular light field with cross hair
markings
· Lamp/Timer Feature; includes spare projection lamp
· Swivel Mount allowing 360° with 90° detents
· Radiation field size scale for 40” & 72” SID (100cm & 180cm)
· Integrated SID tape measure |
|